TRD i kveldAlle arrangementer →
Foredrag & kurs

Defense of thesis – 7 December – Hugo Rodrigues de Brito, Faculty of Information Technology and Electrical Engineering

Illustrasjon for Defense of thesis – 7 December – Hugo Rodrigues de Brito, Faculty of Information Technology and Electrical Engineering
Nårmandag 7. desember 2026 · 09:00
StedRådsrommet, G144
PrisPris ikke oppgitt
AdresseRådsrommet, G144

Doctoral candidate Hugo Rodrigues de Brito at the Department of Electric Energy will hold a trial lecture and defend his doctoral thesis for the degree of Philosophiae Doctor (PhD.) Thesis title Hierarchical Voltage Regulation for Improved Transmission Grid Operation Trial Lecture Voltage stability in modern power systems with high penetration of inverter-based generation and load Time and venue The PhD trial lecture and defense are both open to the public: Trial lecture : 7 December 2026 at 09:00– G144, Rådsrommet, Electro Building, Gløshaugen, NTNU Defense of thesis: 7 December 2026 at 11:15 – G144, Rådsrommet, Main Building, Gløshaugen, NTNU You may also follow the defense online: Teams Meeting Assessment Committe First opponent: Professor Jako Kilter, Talinn University of Technology Second opponent : Dr Tatiana Mariano Lessa de Assis, National Grid, UK Internal member: Associate Professor Sjur Føyen, Department of Electric Energy, NTNU Associate Professor Sjur Føyen, Department of Electric Energy, NTNU, is appointed as the administrator of the assessment committee. The committee has concluded that the thesis is worthy of public defense for the PhD degree. Supervisors Main supervisor: Professor Kjetil Obstfelder Uhlen Co-supervisor: Professor Thomas Øyvang, USN Abstract This thesis focuses on the conceptualization, analytical assessment and dynamic performance of a hierarchical voltage regulation scheme tailored to the characteristics of realistic transmission networks, such as a certain portion of the Norwegian power system. The proposed framework follows the conventional three-level architecture, and the importance of each level is highlighted through simulations and associated discussions of key parameters vis-à-vis grid cost-effectiveness and robustness. Several test systems are employed in case studies, along with a proprietary model equivalent representing a specific Norwegian grid subsystem. The first contribution of this work refers to the dynamic interactions between the developed approach and reactive power resources of interest within the systems under analysis, namely: synchronous generators equipped with automatic voltage regulators and over-excitation limiters, on-load tap changers, static VAr compensators and wind power plants. Comparative evaluations of different control configurations play a crucial role in identifying the merits of the hierarchical framework regarding system stability and overall performance in the presence of these VAr resources. The second contribution of this work refers to the application of the proposed scheme, following initial test system assessments, towards improving daily operation of a Norwegian grid subsystem in terms of minimizing active power losses and maximizing both operating reserves and loadability. A two-stage Pareto-based optimization is used to investigate the intricate interplay among such objectives, and the overarching hierarchy is validated across different combinations of control layers, levels of support from VAr devices and number of objective functions considered. The end goal is to provide a detailed analysis of benefits and drawbacks associated with the scheme as a prospective means of achieving realistic gains (cost savings, expanded reserves, etc.) for the transmission system operator. Collectively, the overall body of contributions pertaining to this thesis aims to facilitate control center operator routines with respect to daily real-time voltage control practices, paving the way for more cost-effective and robust transmission networks

Les mer hos arrangøren ↗
Legg i kalender

Apple Kalender / iPhone

Google Kalender

Outlook

Sluttid mangler. Kalenderforslaget varer i 2 timer. Dette er en kopi som ikke oppdateres automatisk.

Sjekk arrangørens side før du drar. Tid, pris og tilgjengelighet kan endres.